Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrasound Obstet Gynecol ; 62(3): 448-449, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37647041
2.
Ultrasound Obstet Gynecol ; 61(2): 275-277, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36722426
3.
Ultrasound Obstet Gynecol ; 59(5): 651-659, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34558747

RESUMO

OBJECTIVES: Two-dimensional speckle-tracking echocardiography (2D-STE) is a promising technique which allows assessment of fetal cardiac function, and can be used in the evaluation of cardiac and non-cardiac diseases in pregnancy. However, reliable fetal reference values for deformation parameters measured using 2D-STE are needed before it can be introduced into clinical practice. This study aimed to obtain reference values for fetal global longitudinal strain (GLS) and GLS rate (GLSR) measured using 2D-STE and compare right and left ventricular values. METHODS: This was a prospective longitudinal cohort study of uncomplicated pregnancies that underwent echocardiography every 4 weeks from inclusion at 18-21 weeks until delivery to obtain four-chamber loops of the fetal heart. Left and right ventricular GLS and GLSR were measured using 2D-STE at each examination. Using Bayesian mixed-effects models, reference values with lower and upper 5% prediction limits were calculated according to gestational age. Right and left ventricular GLS values according to gestational age were compared using the Wilcoxon signed-rank test. RESULTS: A total of 592 left ventricular and 566 right ventricular GLS and GLSR measurements were obtained from 124 women with uncomplicated pregnancy and non-anomalous, appropriately grown fetuses. Reference values were obtained for both fetal ventricles according to gestational week. GLS and GLSR values of both ventricles increased (i.e. became less negative) significantly during pregnancy. Right ventricular GLS values were significantly higher (i.e. less negative) than the respective left ventricular values at every gestational week. CONCLUSIONS: Reference values were obtained for fetal GLS and GLSR measured using 2D-STE. GLS and GLSR values increased significantly for both ventricles from the second trimester until delivery. GLS values were significantly higher for the right ventricle compared with the left ventricle. Future studies are needed to assess whether the obtained reference values are helpful in clinical practice in the assessment of pregnancy complications, such as fetal growth restriction or cardiac anomaly. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Ecocardiografia , Ultrassonografia Pré-Natal , Teorema de Bayes , Ecocardiografia/métodos , Feminino , Coração Fetal/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Estudos Longitudinais , Masculino , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Função Ventricular Esquerda
4.
BMC Pregnancy Childbirth ; 21(1): 791, 2021 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-34823483

RESUMO

BACKGROUND: Worldwide, hypertensive disorders of pregnancy (HDP), fetal growth restriction (FGR) and preterm birth remain the leading causes of maternal and fetal pregnancy-related mortality and (long-term) morbidity. Fetal cardiac deformation changes can be the first sign of placental dysfunction, which is associated with HDP, FGR and preterm birth. In addition, preterm birth is likely associated with changes in electrical activity across the uterine muscle. Therefore, fetal cardiac function and uterine activity can be used for the early detection of these complications in pregnancy. Fetal cardiac function and uterine activity can be assessed by two-dimensional speckle-tracking echocardiography (2D-STE), non-invasive fetal electrocardiography (NI-fECG), and electrohysterography (EHG). This study aims to generate reference values for 2D-STE, NI-fECG and EHG parameters during the second trimester of pregnancy and to investigate the diagnostic potential of these parameters in the early detection of HDP, FGR and preterm birth. METHODS: In this longitudinal prospective cohort study, eligible women will be recruited from a tertiary care hospital and a primary midwifery practice. In total, 594 initially healthy pregnant women with an uncomplicated singleton pregnancy will be included. Recordings of NI-fECG and EHG will be made weekly from 22 until 28 weeks of gestation and 2D-STE measurements will be performed 4-weekly at 16, 20, 24 and 28 weeks gestational age. Retrospectively, pregnancies complicated with pregnancy-related diseases will be excluded from the cohort. Reference values for 2D-STE, NI-fECG and EHG parameters will be assessed in uncomplicated pregnancies. After, 2D-STE, NI-fCG and EHG parameters measured during gestation in complicated pregnancies will be compared with these reference values. DISCUSSION: This will be the a large prospective study investigating new technologies that could potentially have a high impact on antepartum fetal monitoring. TRIAL REGISTRATION: Registered on 26 March 2020 in the Dutch Trial Register (NL8769) via https://www.trialregister.nl/trials and registered on 21 October 2020 to the Central Committee on Research Involving Human Subjects (NL73607.015.20) via https://www.toetsingonline.nl/to/ccmo_search.nsf/Searchform?OpenForm .


Assuntos
Ecocardiografia/métodos , Eletrocardiografia/métodos , Diagnóstico Pré-Natal/métodos , Adulto , Feminino , Retardo do Crescimento Fetal/diagnóstico , Frequência Cardíaca Fetal/fisiologia , Humanos , Hipertensão Induzida pela Gravidez/diagnóstico , Estudos Longitudinais , Países Baixos , Gravidez , Segundo Trimestre da Gravidez , Nascimento Prematuro/diagnóstico , Estudos Prospectivos , Monitorização Uterina , Útero/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...